---
title: "Infrastructure"
description: ""
url: "https://www.redcables.it/en/services/infrastructure"
date: "2026-06-17T21:19:47+00:00"
language: "en-GB"
---

Redcables operates in the assessment, rehabilitation, and upgrading of infrastructures and special structures, including lighting towers, pylons, steel structures, and telecommunications facilities.
The approach is primarily structural and can be integrated with electrical works, permitting activities, and on-site operations management.

Activities include:

- structural diagnostics through surveys and non-destructive testing;
- static and dynamic analyses and FEM modeling;
- design of strengthening, reinforcement, and upgrades to accommodate new loads;
- planned maintenance programs and retrofit interventions.

Non-destructive testing (ultrasonic testing, magnetic particle inspection, rebound hammer testing, endoscopic inspections) is carried out by personnel certified according to UNI EN ISO 9712 standards, without interrupting the operation of the structures.

## Schema

```json
{ "@context": "https://schema.org", "@type": "BreadcrumbList", "itemListElement": [ { "@type": "ListItem", "position": 1, "name": "Home", "item": "https://www.redcables.it/en" }, { "@type": "ListItem", "position": 2, "name": "Infrastructure", "item": "https://www.redcables.it/en/services/infrastructure" } ] }
```

```json
{ "@context": "https://schema.org", "@type": "Service", "name": "Infrastructure", "serviceType": "Infrastructure", "description": "<p data-start="111" data-end="451">Redcables operates in the assessment, rehabilitation, and upgrading of infrastructures and special structures, including lighting towers, pylons, steel structures, and telecommunications facilities.<br data-start="309" data-end="312" />The approach is primarily structural and can be integrated with electrical works, permitting activities, and on-site operations management.</p> <p data-start="453" data-end="472">Activities include:</p> <ul data-start="474" data-end="737"> <li data-start="474" data-end="545"> <p data-start="476" data-end="545">structural diagnostics through surveys and non-destructive testing;</p> </li> <li data-start="546" data-end="595"> <p data-start="548" data-end="595">static and dynamic analyses and FEM modeling;</p> </li> <li data-start="596" data-end="678"> <p data-start="598" data-end="678">design of strengthening, reinforcement, and upgrades to accommodate new loads;</p> </li> <li data-start="679" data-end="737"> <p data-start="681" data-end="737">planned maintenance programs and retrofit interventions.</p> </li> </ul> <p data-start="739" data-end="993" data-is-last-node data-is-only-node>Non-destructive testing (ultrasonic testing, magnetic particle inspection, rebound hammer testing, endoscopic inspections) is carried out by personnel certified according to UNI EN ISO 9712 standards, without interrupting the operation of the structures.</p>", "image": "https://www.redcables.it/", "url": "https://www.redcables.it/en/services/infrastructure", "provider": { "@type": "Organization", "name": "Redcables : Servizi di ingegneria integrata", "image": "https://www.redcables.it/images/new-logo-rosso_2025-01.png", "telephone": "+390413121554", "address": { "@type": "PostalAddress", "streetAddress": "Via Roma 101", "addressCountry": "IT", "addressLocality": "Quarto d'Altino", "addressRegion": "Veneto", "postalCode": "30020" } }, "offers": { "@type": "Offer", "price": "0.00", "priceCurrency": "USD" } }
```
